Tuesday, August 8, 2023

Non-Invasive Flow Measurements for Sewage

Testing the Portasonic® 2.FL0 Ultrasonic Flowmeter at a UAE-based Sewage Treatment Plant.

The primary objective of the case study was to perform an onsite demonstration and live tests of the Portasonic® 2.FL0 on two distinct pipelines:

  1. The Treated Water Inlet line, which is equipped with two different flow meters (1 analog flow meter and 1 digital inline flow meter).
  2. The RO Water line, also featuring an inline flow meter.

This study was carried out at the Government Sewage Treatment Plant in Al Ghail Gate, Ras Al Khaimah, UAE. The purpose was to validate the accuracy of the existing inline and analog flow meters in comparison to the Portasonic® 2.FL0. This comparison was conducted while measuring the flow rate of liquid in both the Treated Water Inlet line and the RO Water line.

Upon configuring the settings correctly and ensuring proper sensor installation, the Portasonic® 2.FL0 demonstrated its capability to accurately and consistently measure flow rates in both the Treated Water Inlet line and RO Water line. The accuracy ranged between 0.5% and 1%

https://coltraco.com/case-study-case-study-successful-onsite-application-and-testing-of-the-portasonic-2-fl0-at-a-uae-based-sewage-treatment-plant/

No comments: